H72Dimplex · LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

H72 on a Dimplex LA MI inverter outdoor air-to-water: Hot water tank temperature sensor misreading

Short answer

On a Dimplex heat pump, H72 means: Hot water tank temperature sensor misreading. The heat pump keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Hot water tank temperature sensor misreading.

Part involved: Tank sensor (NTC-2, 2.0 kOhm at 25C).

When it shows: Tank connection ON and tank sensor error for 5 s.

Likely causes:

  • Faulty connector connection.
  • Faulty NTC-2 sensor.
  • Faulty main water PCB.

Is it safe?

Does the heat pump stop?Partly
Engineer needed?Yes

The heat pump keeps running with some functions stopped.

Resetting itself: unknown.

Manual reset: Clear via control panel per Dimplex article (method shown as image).

What you can check

  • Note the code and contact the installer or Dimplex service.

What the engineer will check

  • Isolate the heat pump from mains before any work.
  • Check sensor resistance at known temperature.
  • Replace probe X-029379 or water PCB.

Who to ask for: heat pump service engineer / heating engineer.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026