H23Dimplex · LA MI inverter outdoor air-to-water (LA 6/9/12/16 MI)

H23 on a Dimplex LA MI inverter outdoor air-to-water: Refrigerant liquid temperature sensor defective or disconnected

Short answer

On a Dimplex heat pump, H23 means: Refrigerant liquid temperature sensor defective or disconnected. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Refrigerant liquid temperature sensor defective or disconnected.

Part involved: Refrigerant liquid temperature sensor (CN-TH1 loom).

Likely causes:

  • Sensor disconnected.
  • Sensor defective.
  • Main water PCB.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Clear via control panel per Dimplex article (method shown as image).

What you can check

  • Until an engineer attends, switch on the electric backup per the Dimplex guide 'How do I switch on the backup on the LA-MI heat pump?' (GDHV help centre).
  • Note the code and contact the installer or Dimplex service.

What the engineer will check

  • Isolate the heat pump from mains before any work.
  • Check CN-TH1 on main water PCB.
  • Check probe resistance.

Who to ask for: heat pump service engineer / heating engineer.

Certification: Electrical competence (Part P / qualified electrician) for work inside control panels.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026