PPBaxi

PP on a Baxi heat pump: Water inlet temperature higher than water outlet in heating mode

Short answer

On a Baxi heat pump, PP means: Water inlet temperature higher than water outlet in heating mode. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Water inlet temperature higher than water outlet in heating mode.

Part involved: water flow / pressure.

Likely causes:

  • Inlet/outlet sensor connector loose; TW_in/TW_out sensor broken; four-way valve blocked (restart) or broken - replace.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Tw_out - Tw_in unusual protection.

Part involved: water flow / pressure.

Likely causes:

  • Check resistance and location of the two sensors; inlet/outlet sensor connector loose; Tw_in/Tw_out sensor broken; four-way valve blocked (restart unit) or broken.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Protection against an abnormal temperature difference between the water outlet and inlet.

Part involved: water flow / pressure.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Read the heating system pressure gauge and report the value to your installer (the manuals quote a minimum of about 1 bar cold).
  • Check the filling loop is closed.
  • In freezing weather do not leave the system switched off - the manuals warn water faults left unrepaired in winter can let the pump and pipes freeze.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Inlet/outlet sensor connector loose; TW_in/TW_out sensor broken; four-way valve blocked (restart) or broken - replace.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Check resistance and location of the two sensors; inlet/outlet sensor connector loose; Tw_in/Tw_out sensor broken; four-way valve blocked (restart unit) or broken.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026