E1Baxi

E1 on a Baxi heat pump: Phase sequence fault (three-phase unit only)

Short answer

On a Baxi heat pump, E1 means: Phase sequence fault (three-phase unit only). The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Phase sequence fault (three-phase unit only).

Part involved: power supply / PCB.

Likely causes:

  • Check supply cables connected firmly (phase loss); change sequence of any two of the three supply cables.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Phase loss or neutral and live wire connected reversely (three-phase units only).

Part involved: power supply / PCB.

Likely causes:

  • Check supply cables firmly connected (phase loss); check neutral/live sequence.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Phase loss or phase reversal.

Part involved: power supply / PCB.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the heat pump's consumer-unit breaker / isolator is on (do not open any panels).
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Check supply cables connected firmly (phase loss); change sequence of any two of the three supply cables.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Check supply cables firmly connected (phase loss); check neutral/live sequence.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026