E8 on a Baxi heat pump: Water flow failure

Short answer

On a Baxi heat pump, E8 means: Water flow failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Water flow failure.

Part involved: water flow / pressure.

Likely causes:

  • Shut-off valves not fully open; filter needs cleaning; air in system; water pressure must be >1 bar; pump speed not highest; expansion vessel broken; circuit resistance too high for pump; during defrost check backup heater supply/fuses; pump fuse and PCB fuse.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Water flow failure.

Part involved: water flow / pressure.

Likely causes:

  • Shut-off valves not fully open; water filter needs cleaning; air in system (purge); water pressure must be >1 bar; pump speed not on highest; expansion vessel broken; circuit resistance too high for pump; during defrost check backup heater supply wiring/fuses; pump fuse or PCB fuse blown.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Water flow protection.

Part involved: water flow / pressure.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Read the heating system pressure gauge and report the value to your installer (the manuals quote a minimum of about 1 bar cold).
  • Check the filling loop is closed.
  • In freezing weather do not leave the system switched off - the manuals warn water faults left unrepaired in winter can let the pump and pipes freeze.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Shut-off valves not fully open; filter needs cleaning; air in system; water pressure must be >1 bar; pump speed not highest; expansion vessel broken; circuit resistance too high for pump; during defrost check backup heater supply/fuses; pump fuse and PCB fuse.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Shut-off valves not fully open; water filter needs cleaning; air in system (purge); water pressure must be >1 bar; pump speed not on highest; expansion vessel broken; circuit resistance too high for pump; during defrost check backup heater supply wiring/fuses; pump fuse or PCB fuse blown.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026