E0Baxi

E0 on a Baxi heat pump: Flow switch error (E8 displayed 3 times)

Short answer

On a Baxi heat pump, E0 means: Flow switch error (E8 displayed 3 times). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Flow switch error (E8 displayed 3 times).

Part involved: water flow / pressure.

Likely causes:

  • Wire short-circuited or open; water flow rate too low; water flow switch failed (open/closed continuously) - change flow switch.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Water flow fault (after 3 times E8).

Part involved: water flow / pressure.

Likely causes:

  • Wire circuit short-circuited or open; water flow rate too low; water flow switch failed (open or closed continuously) - replace flow switch.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Water flow error (10 times E8).

Part involved: water flow / pressure.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Read the heating system pressure gauge and report the value to your installer (the manuals quote a minimum of about 1 bar cold).
  • Check the filling loop is closed.
  • In freezing weather do not leave the system switched off - the manuals warn water faults left unrepaired in winter can let the pump and pipes freeze.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Wire short-circuited or open; water flow rate too low; water flow switch failed (open/closed continuously) - change flow switch.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Wire circuit short-circuited or open; water flow rate too low; water flow switch failed (open or closed continuously) - replace flow switch.

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: None beyond heating competence (MCS installer recommended).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026