Heat pumps · Error codes · Baxi
PdBaxi

Pd on a Baxi heat pump: High temperature protection of refrigerant outlet temp of condenser

Short answer

On a Baxi heat pump, Pd means: High temperature protection of refrigerant outlet temp of condenser. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: High temperature protection of refrigerant outlet temp of condenser.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Heat exchanger cover not removed; heat exchanger blocked (clean); insufficient space around unit; fan motor broken.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: High temperature protection of refrigerant outlet temp of condenser.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Heat exchanger cover not removed; heat exchanger dirty/blocked; insufficient space around unit; fan motor broken.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Listed twice: 'Frost protection operation' (Tab.36 Others, Main Control PCB) and 'Protection against excessive condensation temperature' (Tab.37 Protection codes, user interface).

Part involved: refrigerant pressure / temperature.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the outdoor unit is not blocked by leaves, debris, snow or covers and has clear airflow.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Heat exchanger cover not removed; heat exchanger blocked (clean); insufficient space around unit; fan motor broken.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Heat exchanger cover not removed; heat exchanger dirty/blocked; insufficient space around unit; fan motor broken.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work; competence with flammable A3 refrigerant R290.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.