P6Baxi

P6 on a Baxi heat pump: Module protection

Short answer

On a Baxi heat pump, P6 means: Module protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 2 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Module protection.

Part involved: inverter module, compressor, PFC.

Likely causes:

  • Supply voltage low; units too close; heat exchanger dirty/blocked; fan not running; refrigerant overcharged; low water flow/air/insufficient pump head; outlet sensor loose; DHW coil too small; module wires/screws loose or thermal paste dried; wire connection loose; drive board defective; compressor defective.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Inverter module protection (L0-L9 sub-codes).

Part involved: inverter module, compressor, PFC.

Likely causes:

  • Check heat pump system pressure; compressor phase resistance; U/V/W connection sequence inverter board-compressor; L1/L2/L3 connection inverter board-filter board; inverter board.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the outdoor unit is not blocked by leaves, debris, snow or covers and has clear airflow.
  • Check the heat pump's consumer-unit breaker / isolator is on (do not open any panels).
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Supply voltage low; units too close; heat exchanger dirty/blocked; fan not running; refrigerant overcharged; low water flow/air/insufficient pump head; outlet sensor loose; DHW coil too small; module wires/screws loose or thermal paste dried; wire connection loose; drive board defective; compressor defective.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Check heat pump system pressure; compressor phase resistance; U/V/W connection sequence inverter board-compressor; L1/L2/L3 connection inverter board-filter board; inverter board.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026