P1Baxi

P1 on a Baxi heat pump: High pressure protection

Short answer

On a Baxi heat pump, P1 means: High pressure protection. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: High pressure protection.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Heating/DHW: low water flow, high water temp, air in system; water pressure <0.1 MPa (charge to 0.15-0.2 MPa); refrigerant overcharged; EEV locked/winding loose; DHW tank coil smaller than required 1.7 m2 (10-16 kW) or 1.4 m2 (5-9 kW). Cooling: heat exchanger cover not removed; heat exchanger dirty/blocked.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: High pressure switch protection.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Heating/DHW: low water flow / high water temp / air in system; water pressure <1 bar (charge to 1.5-2 bar); refrigerant overcharged; EEV locked or winding loose; DHW: tank heat exchanger too small. Cooling: heat exchanger cover not removed; heat exchanger dirty/blocked.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: High pressure switch protection.

Part involved: refrigerant pressure / temperature.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the outdoor unit is not blocked by leaves, debris, snow or covers and has clear airflow.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Heating/DHW: low water flow, high water temp, air in system; water pressure <0.1 MPa (charge to 0.15-0.2 MPa); refrigerant overcharged; EEV locked/winding loose; DHW tank coil smaller than required 1.7 m2 (10-16 kW) or 1.4 m2 (5-9 kW). Cooling: heat exchanger cover not removed; heat exchanger dirty/blocked.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Heating/DHW: low water flow / high water temp / air in system; water pressure <1 bar (charge to 1.5-2 bar); refrigerant overcharged; EEV locked or winding loose; DHW: tank heat exchanger too small. Cooling: heat exchanger cover not removed; heat exchanger dirty/blocked.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work; competence with flammable A3 refrigerant R290.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.