HF on a Baxi heat pump: Main control board PCB B EEprom failure

Short answer

On a Baxi heat pump, HF means: Main control board PCB B EEprom failure. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Main control board PCB B EEprom failure.

Part involved: power supply / PCB.

Likely causes:

  • EEprom parameter error - rewrite; EEprom chip failing - replace; main PCB broken - replace.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Inverter module board EE prom failure.

Part involved: power supply / PCB.

Likely causes:

  • EE prom parameter erroneous - rewrite; EE prom chip broken; inverter module board broken - replace PCB.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Outdoor unit EEPROM error.

Part involved: power supply / PCB.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the heat pump's consumer-unit breaker / isolator is on (do not open any panels).
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • EEprom parameter error - rewrite; EEprom chip failing - replace; main PCB broken - replace.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • EE prom parameter erroneous - rewrite; EE prom chip broken; inverter module board broken - replace PCB.

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump engineer with electrical competence.

Certification: Qualified electrician / manufacturer-trained heat pump engineer; F-gas if refrigerant circuit is opened.