HA on a Baxi heat pump: Plate heat exchanger water outlet temperature sensor (TW_out) error

Short answer

On a Baxi heat pump, HA means: Plate heat exchanger water outlet temperature sensor (TW_out) error. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Plate heat exchanger water outlet temperature sensor (TW_out) error.

Part involved: temperature sensor.

Likely causes:

  • TW_out connector loose or wet; sensor failing - replace.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Outlet water temp. sensor (Tw_out) fault.

Part involved: temperature sensor.

Likely causes:

  • Tw_out connector loose or wet; Tw_out sensor failed - replace.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Tw_out plate heat exchanger outlet water temperature sensor error.

Part involved: temperature sensor.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • TW_out connector loose or wet; sensor failing - replace.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Tw_out connector loose or wet; Tw_out sensor failed - replace.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.