H8Baxi

H8 on a Baxi heat pump: Pressure sensor failure

Short answer

On a Baxi heat pump, H8 means: Pressure sensor failure. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 3 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Pressure sensor failure.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Pressure sensor connector loose; pressure sensor failed - change.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Pressure sensor failure.

Part involved: refrigerant pressure / temperature.

Likely causes:

  • Pressure sensor connector loose; pressure sensor failed - replace.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: H-SEN high pressure sensor error.

Part involved: refrigerant pressure / temperature.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

  • Note the exact code shown on the controller and when it appeared.
  • Check the outdoor unit is not blocked by leaves, debris, snow or covers and has clear airflow.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Pressure sensor connector loose; pressure sensor failed - change.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Pressure sensor connector loose; pressure sensor failed - replace.

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump / refrigeration engineer (F-gas).

Certification: F-gas certification (Category I) for refrigerant work; competence with flammable A3 refrigerant R290.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.