H1 on a Baxi heat pump: Communication error between inverter module PCB A and main control board PCB B

Short answer

On a Baxi heat pump, H1 means: Communication error between inverter module PCB A and main control board PCB B. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause. The wording differs by model range — each is shown below.

Reviewed 23 September 2026 · 4 sources

What it means

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

The manual says: Communication error between inverter module PCB A and main control board PCB B.

Part involved: PCB communication wiring.

Likely causes:

  • Check power to PCB and driver board (indicator light); check wiring between main PCB and driver PCB; replace main PCB and driver board in turn.

On the Geoflo Compact ground source heat pump

The manual says: Display reads H1 with audible alarm.

Part involved: water flow / pressure.

Likely causes:

  • Heat pump overheating because there is no water flow to underfloor/radiators. Remedy (manual): Bleed left-hand water pump (serves underfloor/radiators).

On the HP40 / Baxi Assure HP50 Monobloc ASHP

The manual says: Communication error between inverter module PCB A and main control board PCB B.

Part involved: PCB communication wiring.

Likely causes:

  • Check power to PCB and driver board (indicator light); if lit check wiring between inverter module PCB and main control PCB; replace main PCB and driver board one by one.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

The manual says: Communication error between Main Control PCB and inverter PCB.

Part involved: PCB communication wiring.

Is it safe?

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Power OFF/ON after correcting cause (ISM 13.4).

On the Geoflo Compact ground source heat pump

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: unknown.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: Installer: correct cause then power OFF/ON (ISM 13.4).

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: unknown.

Manual reset: unknown.

What you can check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Note the exact code shown on the controller and when it appeared.
  • If the code persists or returns, contact a heat pump engineer.

On the Geoflo Compact ground source heat pump

  • Note the exact code shown on the controller and when it appeared.
  • Read the heating system pressure gauge and report the value to your installer (the manuals quote a minimum of about 1 bar cold).
  • Check the filling loop is closed.
  • In freezing weather do not leave the system switched off - the manuals warn water faults left unrepaired in winter can let the pump and pipes freeze.
  • If the code persists or returns, contact a heat pump engineer.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Note the exact code shown on the controller and when it appeared.
  • If the code persists or returns, contact a heat pump engineer.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Note the exact code shown on the controller and when it appeared.
  • If the code persists or returns, contact a heat pump engineer.

What the engineer will check

On the Assure Monobloc ASHP (Assure Mono 5/7/9/12/16)

  • Check power to PCB and driver board (indicator light); check wiring between main PCB and driver PCB; replace main PCB and driver board in turn.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

On the Geoflo Compact ground source heat pump

  • Heat pump overheating because there is no water flow to underfloor/radiators. Remedy (manual): Bleed left-hand water pump (serves underfloor/radiators).

Who to ask for: heating / heat pump engineer (hydraulics).

Certification: Heating/GSHP installer competence; F-gas only if refrigerant circuit opened.

On the HP40 / Baxi Assure HP50 Monobloc ASHP

  • Check power to PCB and driver board (indicator light); if lit check wiring between inverter module PCB and main control PCB; replace main PCB and driver board one by one.

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

On the HP60 / Baxi Assure HP55 High Temperature Monobloc ASHP (R290)

  • Diagnose per manufacturer service procedure (manual gives description only).

Who to ask for: heat pump engineer (controls / sensors).

Certification: Manufacturer-trained heat pump engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026