Short answer
Fit dual-supply warning notices at the origin, meter, consumer unit and isolators, label the DC cables and junction boxes, and display the system schematic and emergency shutdown procedure. Batteries need the IET EESS Code of Practice Appendix C labels, with Figures C.2 and C.5 always. Plug-in kits come with a consumer-unit label that must be fitted.
Last checked 24 September 2026 · 1 source
In more detail
- MIS 3012 cl.4.2: documentation to BS EN IEC/IEEE 82079-1; CoP App C labels; C.3 for DC-coupled/bespoke systems with exposed DC terminals; plus BS 7671 labels.
- MIS 3002 App F: all labelling and signage incl. system schematic present; emergency shutdown procedure visible.
- Plug-in spec 8.2.3: durable CU label for the plug-in PV device; plug marked 'one device per circuit', rated current, M002 sign, no extension/adaptors.
- BS 7671 label regulation numbers (514.15 dual supply / 514.9 diagrams) not verified this session.
The facts, dated
- 01EESS CoP labels mandatory in all cases per MIS 3012 — Figures C.2 and C.5
standard · UK · checked 24 September 2026 · MCS