pv-isolation-total on a Tesla Powerwall+: Alert: Isolation Self-Test Failure ('PV Isolation Total' or 'PV Isolation 24Hr Lockout') on Powerwall+/Tesla Solar Inverter

Short answer

On a Tesla inverter, pv-isolation-total means: Alert: Isolation Self-Test Failure ('PV Isolation Total' or 'PV Isolation 24Hr Lockout') on Powerwall+/Tesla Solar Inverter. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Alert: Isolation Self-Test Failure ('PV Isolation Total' or 'PV Isolation 24Hr Lockout') on Powerwall+/Tesla Solar Inverter.

Likely causes:

  • PV array conductor faulting to earth (damaged module, nicked/pinched cable).
  • Strings mixed between inverters.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: no.

What you can check

  • Read the app; contact installer (DC-side fault - no homeowner action).

What the engineer will check

  • IR test each string at 1000 V (>1 MΩ to ground).
  • Inspect for pinched wires, water ingress, damaged modules.

Who to ask for: PV / DC fault finding.

Certification: Tesla Certified Installer (Powerwall is not user-serviceable); electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026