arc-fault-lockout on a Tesla Powerwall+: Five Arc Fault alerts within 24 hours cause an Arc Fault lockout on Powerwall+/Tesla Solar Inverter

Short answer

On a Tesla inverter, arc-fault-lockout means: Five Arc Fault alerts within 24 hours cause an Arc Fault lockout on Powerwall+/Tesla Solar Inverter. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Five Arc Fault alerts within 24 hours cause an Arc Fault lockout on Powerwall+/Tesla Solar Inverter.

Likely causes:

  • Faulty stringing, damaged DC connectors or junction boxes, nicked insulation, faulty MCIs, damaged AC harness.

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeveritySafety lockout
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: no.

What you can check

  • Read the app; contact installer (DC-side fault - no homeowner action).

What the engineer will check

  • Lock-out/tag-out, inspect DC connectors and MPPT jumpers, tug tests, MCI diode/resistance tests; toggle Disabled/Enabled to retry self-tests.

Who to ask for: PV / DC fault finding.

Certification: Tesla Certified Installer (Powerwall is not user-serviceable); electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026