IE31 on a SolaX Power SolaX X1-Hybrid G4: ChargeRelayFault - charge relay fault

Short answer

On a SolaX Power inverter, IE31 means: ChargeRelayFault - charge relay fault. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: ChargeRelayFault - charge relay fault.

Part involved: Grid relay / relay test.

Likely causes:

  • Charge relay fault.

Is it safe?

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: may clear at next start if caused by N-PE issue.

Manual reset: installer.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • The SolaX manual lists 'press the ESC key to restart the inverter' for this code (switch off heavy loads first for overload codes).
  • Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.

What the engineer will check

  • Check N and PE connections and N-PE voltage.
  • Restart.
  • Replace inverter if relay test keeps failing.

Who to ask for: PV installer / electrician.

Certification: Electrician competent in grid-connected PV (BS 7671 Section 712; IET Code of Practice for Grid-connected Solar PV), ideally the original MCS-certified PV installer; brand-approved/trained installer to keep manufacturer warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026