SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SolaX Power
BE05SolaX Power · SolaX X1-Hybrid G4

BE05 on a SolaX Power SolaX X1-Hybrid G4: BMS_ChargeOCP - battery over-charge (charge overcurrent) fault

Short answer

On a SolaX Power battery, BE05 means: BMS_ChargeOCP - battery over-charge (charge overcurrent) fault. The battery keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: BMS_ChargeOCP - battery over-charge (charge overcurrent) fault.

Part involved: Battery BMS internal protection/fault.

Likely causes:

  • Battery BMS-reported condition; manual says contact SolaX (via installer).

Is it safe?

Switch the battery off at its isolator if the code comes back.

Does the battery stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The battery keeps running with some functions stopped.

Resetting itself: protection states may clear when conditions normalise; hardware faults do not.

Manual reset: installer/manufacturer.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Do not open the battery. If it is hot, swollen, smoking or smells, keep away, switch off at the AC isolator if safe and call the installer (and 999 if fire).
  • Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.

What the engineer will check

  • Read BMS logs.
  • Check cell voltages/temperatures.
  • Update BMS firmware if the manual says so.
  • Arrange RMA via installer.

Who to ask for: Battery installer.

Certification: Electrician competent in electrical energy storage (BS 7671 Chapter 57; IET Code of Practice for Electrical Energy Storage Systems), ideally the MCS battery installer (MIS 3012); brand-approved installer to keep warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026