IE02 on a SolaX Power SolaX X1-Hybrid G4: Grid Lost Fault

Short answer

On a SolaX Power inverter, IE02 means: Grid Lost Fault. The inverter stops until the fault clears or is reset.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Grid Lost Fault.

Part involved: Loss-of-mains / anti-islanding.

Likely causes:

  • Power cut.
  • AC connection/breaker off.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes

The inverter stops until the fault clears or is reset.

Resetting itself: yes - restarts after the reconnection time once mains returns.

Manual reset: no.

What you can check

  • Read and note the exact code and time from the inverter display or app (screenshot).
  • Check whether there is a power cut (other lights/sockets, DNO 105 service).
  • Check the solar/battery AC isolator and the consumer-unit breaker/RCD are ON (do not reset a breaker that trips again immediately).
  • Where the SolaX manual says 'press the ESC key to restart the inverter', a homeowner can do that on the display. Steps that say 'disconnect PV+/PV-/battery' are for the installer only.

What the engineer will check

  • Check AC isolator, breaker and terminations at the inverter.
  • Measure L-N voltage at inverter terminals.
  • Check neutral connection.

Who to ask for: PV installer / electrician.

Certification: Electrician competent in grid-connected PV (BS 7671 Section 712; IET Code of Practice for Grid-connected Solar PV), ideally the original MCS-certified PV installer; brand-approved/trained installer to keep manufacturer warranty.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.