SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · SMA Solar Technology AG
8503SMA Solar Technology AG · Sunny Boy Smart Energy

8503 on a SMA Solar Technology AG Sunny Boy Smart Energy: Polarity error on the inverter

Short answer

On a SMA Solar Technology AG inverter, 8503 means: Polarity error on the inverter. The inverter keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Polarity error on the inverter.

Part involved: DC input polarity / string.

When it shows: Polarity error on the inverter.

Likely causes:

  • SMA corrective measures: Check whether a string is connected to input C. If a string that once was connected is not used anymore, the string-failure detection must be reset. Contact Service.

Is it safe?

Does the inverter stop?Partly
Engineer needed?Yes

The inverter keeps running with some functions stopped.

Resetting itself: unknown.

Manual reset: See engineer checks.

What you can check

  • Read the event number and message in the SMA Energy app / Sunny Portal (ennexOS) or the inverter's web interface and note the date/time for your installer. A red LED on the inverter means an event has occurred.
  • Contact your installer - this concerns the DC string wiring.

What the engineer will check

  • Check string connection/polarity on the named input, reverse currents, string design and module defects; reset string-failure detection if an input is no longer used; contact SMA Service.

Who to ask for: MCS PV installer.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026