Solar · Error codes · Sigenergy
1021Sigenergy · SigenStor (EC controller + BAT modules + Gateway)

1021 on a Sigenergy SigenStor: Inverter AC side voltage abnormal. Official suggestion (summarised): Reduce load; check for short circuits; check gateway inverter-side breaker

Short answer

On a Sigenergy inverter, 1021 means: Inverter AC side voltage abnormal. Official suggestion (summarised): Reduce load; check for short circuits; check gateway inverter-side breaker. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Inverter AC side voltage abnormal. Official suggestion (summarised): Reduce load; check for short circuits; check gateway inverter-side breaker.

Likely causes:

  • Off-grid overload/short, gateway inverter-side breaker not closed, grid or generator out of range.

Is it safe?

Does the inverter stop?Yes
SeverityFault — clears by itself when the condition goes
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: n/a.

What you can check

  • Read the alarm code, name and ID in the mySigen app.
  • Report it via mySigen app Support > Troubleshooting (Sigenergy's stated route) or contact your installer.
  • During a power cut, switch off large loads (backup overload).

What the engineer will check

  • Check load circuits for short; check Gateway INV-port breaker.
  • Sub-IDs: ID1 AC overload; ID2 AC short circuit; ID3 AC overvoltage; ID4 AC undervoltage; ID5 overfrequency; ID6 underfrequency.

Who to ask for: battery storage / PV inverter.

Certification: Sigenergy-trained installer; MCS PV/battery installer for certified installs; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026