1006 on a Sigenergy SigenStor: PV string overvoltage. Official suggestion (summarised): Measure string voltage; reduce modules per string per spec

Short answer

On a Sigenergy inverter, 1006 means: PV string overvoltage. Official suggestion (summarised): Measure string voltage; reduce modules per string per spec. The inverter keeps running with some functions stopped. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: PV string overvoltage. Official suggestion (summarised): Measure string voltage; reduce modules per string per spec.

Likely causes:

  • Too many modules in series; open-circuit voltage above maximum input.

Is it safe?

Does the inverter stop?Partly
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter keeps running with some functions stopped.

Resetting itself: unknown.

Manual reset: n/a.

What you can check

  • Read the alarm code, name and ID in the mySigen app.
  • Report it via mySigen app Support > Troubleshooting (Sigenergy's stated route) or contact your installer.

What the engineer will check

  • Measure Voc per string (cold-weather Voc).
  • Redesign string length.
  • Sub-IDs: ID1-ID16 string 1-16 input overvoltage; ID17-ID40 MPPT1-24 input overvoltage.

Who to ask for: battery storage / PV inverter.

Certification: Sigenergy-trained installer; MCS PV/battery installer for certified installs; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026