Solar · Error codes · Sigenergy
1018Sigenergy · SigenStor (EC controller + BAT modules + Gateway)

1018 on a Sigenergy SigenStor: Communication fault. Official suggestion (summarised): ID1 top up 4G/reseat dongle; ID2 restart; ID3/ID4 check comms ports

Short answer

On a Sigenergy inverter, 1018 means: Communication fault. Official suggestion (summarised): ID1 top up 4G/reseat dongle; ID2 restart; ID3/ID4 check comms ports. The inverter keeps running with some functions stopped.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Communication fault. Official suggestion (summarised): ID1 top up 4G/reseat dongle; ID2 restart; ID3/ID4 check comms ports.

Likely causes:

  • 4G data exhausted/SIM absent; CAN connector contact; meter or gateway comms connector.

Is it safe?

Does the inverter stop?Partly
SeverityWarning

The inverter keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: n/a.

What you can check

  • Read the alarm code, name and ID in the mySigen app.
  • Report it via mySigen app Support > Troubleshooting (Sigenergy's stated route) or contact your installer.
  • For 4G: check the Sigen CommMod data plan in the app.
  • Restart via the mySigen app (owner account can issue standby/shutdown then startup).

What the engineer will check

  • Reseat 4G dongle; check CAN/meter/gateway comms wiring.
  • Sub-IDs: ID1 4G communication; ID2 CAN communication; ID3 meter communication; ID4 Gateway communication.

Who to ask for: battery storage / PV inverter.

Certification: Sigenergy-trained installer; MCS PV/battery installer for certified installs; electrical work to BS 7671.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026