Solar · Error codes · GoodWe Technologies Co., Ltd.
isolation-failureGoodWe Technologies Co., Ltd. · GoodWe DNS (2.9-6 kW)

isolation-failure on a GoodWe Technologies Co., Ltd. GoodWe DNS: Isolation Failure

Short answer

On a GoodWe Technologies Co., Ltd. inverter, isolation-failure means: Isolation Failure. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: Isolation Failure.

Part involved: Isolation Failure.

Likely causes:

  • Check impedance between ground and PV(+)/PV(-) (>100 kOhm); ensure inverter grounded; contact service.

Is it safe?

Does the inverter stop?Yes
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: unknown.

Manual reset: See checks.

What you can check

  • Read the message on the inverter LCD or in the SEMS Portal app and note it for your installer.
  • Do not touch panels, DC cables or the inverter; contact your installer.

What the engineer will check

  • Insulation resistance test PV+/PV- to earth (>100 kOhm); check inverter earthing.

Who to ask for: GoodWe-trained PV installer.

Certification: Qualified electrician (BS 7671; MCS-certified PV installer for work on the PV array/DC side).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026