Solar · Error codes · Fox ESS
PvCon Dir FaultFox ESS · H1 G2 single-phase hybrid inverter

PvCon Dir Fault on a Fox ESS H1 G2 single-phase hybrid inverter: The PV connection is reversed

Short answer

On a Fox ESS inverter, PvCon Dir Fault means: The PV connection is reversed. The inverter stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: The PV connection is reversed.

Part involved: PV string polarity.

When it shows: Reverse polarity detected on PV input.

Likely causes:

  • PV positive/negative reversed (installation error).

Is it safe?

Switch the inverter off at its isolator and call an engineer.

Does the inverter stop?Yes
SeverityFault — needs a manual reset once the cause is fixed
Engineer needed?Yes

The inverter stops until the fault clears or is reset.

Resetting itself: no.

Manual reset: Installer must correct polarity.

What you can check

  • Read the full code and message on the inverter screen or in the FoxCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • Do not operate the DC isolator; call the installer.

What the engineer will check

  • Verify string polarity with meter before reconnecting; correct connectors.

Who to ask for: MCS-certified solar PV installer (DC/string work) or the original installer.

Certification: Work on DC strings and inverter enclosures: competent PV installer (MCS-certified installer for warranty/SEG continuity); electrical work notifiable under Part P (England & Wales) or equivalent.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026