SolarpunkHomes
Sign inCall us · +44 7510 081687
Solar
Solar · Error codes · Fox ESS
BMS LostFox ESS · H1 G2 single-phase hybrid inverter

BMS Lost on a Fox ESS H1 G2 single-phase hybrid inverter: The communication between BMS and Inverter is interrupted

Short answer

On a Fox ESS battery, BMS Lost means: The communication between BMS and Inverter is interrupted. The battery keeps running with some functions stopped.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: The communication between BMS and Inverter is interrupted.

Part involved: battery BMS communication (CAN).

When it shows: No CAN communication from BMS.

Likely causes:

  • BMS communication cable loose/faulty, battery switched off or asleep.

Is it safe?

Does the battery stop?Partly
SeverityWarning

The battery keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: Check BMS communication cable.

What you can check

  • Read the full code and message on the inverter screen or in the FoxCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).
  • Check that the battery's own power switch/indicator shows it is on (only the external switch/LED the manual shows users; do not open covers).

What the engineer will check

  • Check BMS CAN cable, terminations, battery DIP switches and BMS firmware; power-cycle battery per Fox procedure.

Who to ask for: Battery/hybrid installer trained on the specific battery (manufacturer-approved installer).

Certification: Battery and hybrid-inverter DC work: installer trained/approved by the manufacturer; electrical work under BS 7671 by a competent person.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 24 September 2026