Pv Volt Fault on a Fox ESS H1 G2 single-phase hybrid inverter: PV voltage out of range

Short answer

On a Fox ESS inverter, Pv Volt Fault means: PV voltage out of range. The inverter keeps running with some functions stopped.

Reviewed 24 September 2026 · 1 source

What it means

The manual says: PV voltage out of range.

Part involved: PV input voltage.

When it shows: PV voltage outside inverter limits.

Likely causes:

  • String voltage above/below inverter range (design error, too many modules in series on a cold day).

Is it safe?

Does the inverter stop?Partly
SeverityFault — clears by itself when the condition goes

The inverter keeps running with some functions stopped.

Resetting itself: yes.

Manual reset: Seek help if it persists.

What you can check

  • Read the full code and message on the inverter screen or in the FoxCloud app and note the date/time for your installer.
  • Check the inverter's AC isolator next to the inverter and the solar/battery breaker in the consumer unit are ON (do not reset a breaker that trips again - call your installer).

What the engineer will check

  • Measure string Voc; check string design against 600 V max input (H1 G2); correct stringing.

Who to ask for: MCS-certified solar PV installer (DC/string work) or the original installer.

Certification: Work on DC strings and inverter enclosures: competent PV installer (MCS-certified installer for warranty/SEG continuity); electrical work notifiable under Part P (England & Wales) or equivalent.