DF on a Viessmann Vitotronic 200: Flow switch: Heat pump does not start

Short answer

On a Viessmann heat pump, DF means: Flow switch: Heat pump does not start. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow switch: Heat pump does not start.

Part involved: Flow switch.

When it shows: Heat pump does not start.

Likely causes:

  • Flow switch well circuit has responded.
  • Well circuit flow switch is sticking.
  • Well circuit circulation pump faulty.
  • No jumper inserted across X3.3/X3.4.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check well circuit flow rate.
  • Check well pump. If no flow switch is installed, insert a jumper across X3.3/X3.4; see luster terminals. The flow switch signal can be checked against ….

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.