Heat pumps · Error codes · Viessmann
0AViessmann · Vitotronic 200

0A on a Viessmann Vitotronic 200: Short circuit/lead break, low pressure sensor

Short answer

On a Viessmann heat pump, 0A means: Short circuit/lead break, low pressure sensor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, low pressure sensor.
  • Short circuit/lead break, low pressure sensor (suction gas pressure sensor).
  • External unit: The external unit switches off.

Part involved: Short circuit/lead break, low pressure sensor; Short circuit/lead break, low pressure sensor (suction gas pressure sensor); External unit.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Both compressors OFF The external unit switches off.

Likely causes:

  • Short circuit/lead break, low pressure sensor.
  • Short circuit/lead break, low pressure sensor (suction gas pressure sensor).
  • Number of registered events in the external unit has exceeded the message threshold.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Test voltage at the low pressure sensor connection: See "EEV PCB [2] ". 0.5 V: 0 bar.
  • 4.5 V: Max. pressure, see sensor imprint.
  • Check current at connection J10 (P1) of the EEV PCB: See "EEV PCB [4-3] / [4-4] ". Take refrigerant R410A into account.
  • Check current at connection J10 (P1) of the EEV PCB: See "EEV PCB [4-6] / [4-7] ". Take refrigerant R410A into account.
  • Check current at connection J10 (P1) on the EEV PCB: See "EEV PCB [4] ". Take refrigerant R410A into account.
  • Test voltage at the low pressure sensor connection on the EEV PCB: See "controller PCB and EEV PCB [6] ". 0.5 V: 0 bar.
  • Observe messages from the refrigerant circuit controller: "Diagnosis" "Refrigerant circuit" "Message statistics".
  • Observe values displayed for the temperature and pressure sensors: "Diagnosis" "Refrigerant circuit" "External unit" Replace sensors if required.
  • Check position of the DIP switch in the external unit.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026