Heat pumps · Error codes · Viessmann
0DViessmann · Vitotronic 200

0D on a Viessmann Vitotronic 200: Short circuit/lead break, coding resistor

Short answer

On a Viessmann heat pump, 0D means: Short circuit/lead break, coding resistor. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Short circuit/lead break, coding resistor.
  • Test mode ext. unit: Heat pump heats or cools with a constant flow temper- Set flow temperature for test mode: ature in the secondary circuit; secondary pump is star-; Cooling ….

Part involved: Short circuit/lead break, coding resistor; Test mode ext. unit.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Heat pump heats or cools with a constant flow temper- Set flow temperature for test mode: ature in the secondary circuit; secondary pump is star-; Cooling 16 ° C ted.; Heating 30 ° C.

Likely causes:

  • Short circuit/lead break, coding resistor.
  • External unit in test mode.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Check resistance at connection J10 (P3) on the EEV PCB.
  • If necessary, contact Viessmann Werke technical services.
  • Test mode ends automatically after 60 min.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.