Heat pumps · Error codes · Viessmann
DDViessmann · Vitotronic 200

DD on a Viessmann Vitotronic 200: Ctrl high pressure 2: Compressor heat pump stage 2 stops

Short answer

On a Viessmann heat pump, DD means: Ctrl high pressure 2: Compressor heat pump stage 2 stops. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Ctrl high pressure 2: Compressor heat pump stage 2 stops.

Part involved: Ctrl high pressure 2.

When it shows: Compressor heat pump stage 2 stops.

Likely causes:

  • High pressure fault, heat pump stage 2 (if installed):.
  • Air in heating circuit.
  • Secondary pump or heating circuit pump blocked.
  • Condenser contaminated.
  • High pressure sensor faulty.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Vent heating circuit.
  • Check system pressure.
  • Check secondary pump and heating circuit pumps.
  • Flush heating circuits. Note In rare cases, e.g. during DHW heating, a high pressure fault can occur. If this occurs several times in succession, the ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026