Heat pumps · Error codes · Viessmann
DCViessmann · Vitotronic 200

DC on a Viessmann Vitotronic 200: Low pressure 2: Compressor heat pump stage 2 stops

Short answer

On a Viessmann heat pump, DC means: Low pressure 2: Compressor heat pump stage 2 stops. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Low pressure 2: Compressor heat pump stage 2 stops.

Part involved: Low pressure 2.

When it shows: Compressor heat pump stage 2 stops.

Likely causes:

  • Low pressure fault, heat pump stage 2 (if installed):.
  • Heat pump faulty.
  • Primary pump faulty.
  • Low pressure switch has responded.
  • Low pressure sensor has issued a fault message.
  • Low pressure sensor faulty.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Have heat pump checked by a refrigeration engineer.
  • Check pressure gauge, primary pump and shut-off facilities.
  • Check low pressure sensor, lead and EEV PCB; replace if necessary. The signal at plug aYH can be measured at connection 214.3 (see "Main PCB"). ….
  • Appliances with low pressure sensor : Jumper set across terminals 116.3/116.4. Signal must be permanently present (230 V~).
  • Appliances with low pressure switch : No jumper across terminals 116.3/116.4. There is no signal if the pressure switch has responded (0 V).

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026