Heat pumps · Error codes · Viessmann
DBViessmann · Vitotronic 200

DB on a Viessmann Vitotronic 200: Refrig. circ (SHD) 2: Compressor heat pump stage 2 stops

Short answer

On a Viessmann heat pump, DB means: Refrig. circ (SHD) 2: Compressor heat pump stage 2 stops. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Refrig. circ (SHD) 2: Compressor heat pump stage 2 stops.

Part involved: Refrig. circ (SHD) 2.

When it shows: Compressor heat pump stage 2 stops.

Likely causes:

  • Fault, refrigerant circuit, heat pump stage 2 (if installed):.
  • Safety high pressure switch has responded.
  • Compressor motor overload relay (thermal relay) has responded.
  • Start-up resistor (Klixon) temperature switch has responded.
  • Separate compressor motor overload relay (if installed) has responded.

Is it safe?

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Measure text: "After removing the fault, switch the appliance first off and then on again.".

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check flow and return temperature sensors in primary and secondary circuits.
  • Check primary and secondary circuits for pressure and flow rate (see also message "A9 Heat pump").
  • Have heat pump checked by a refrigeration engineer. The switching signal of the high pressure switch can be checked at terminals 214.2, 214.4 (see "Main ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.