DA on a Viessmann Vitotronic 200: Compressor 2, safety: Compressor heat pump stage 2 stops

Short answer

On a Viessmann heat pump, DA means: Compressor 2, safety: Compressor heat pump stage 2 stops. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Compressor 2, safety: Compressor heat pump stage 2 stops.

Part involved: Compressor 2, safety.

When it shows: Compressor heat pump stage 2 stops.

Likely causes:

  • Compressor fault, heat pump stage 2:.
  • Thermal compressor relay or safety element of full wave soft starter (if installed) has responded.
  • Separate compressor motor overload relay (if installed) has responded.
  • Start-up resistor (Klixon) temperature switch has responded.
  • Phase monitor has recognised a fault.
  • Phase monitor faulty.

Is it safe?

Does the heat pump stop?Not stated
SeveritySafety lockout
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Reset thermal relay on compressor, check thermal relay setting, restore delivered condition of control unit ("Standard setting").
  • Check electrical connections on compressor, test winding resistance of compressor motor. Check phase sequence on compressor.
  • If necessary, replace start-up resistor or full wave soft starter (if installed); have compressor checked by a refrigeration engineer. The switching signal of the thermal ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026