D6Viessmann · Vitotronic 200

D6 on a Viessmann Vitotronic 200: Flow switch: Compressor stops

Short answer

On a Viessmann heat pump, D6 means: Flow switch: Compressor stops. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Flow switch: Compressor stops.

Part involved: Flow switch.

When it shows: Compressor stops.

Likely causes:

  • Minimum flow rate in secondary circuit is undershot: See heat pump specification. Heat pump specification Heat pump installation and service instructions.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check secondary circuit flow rate.
  • Check secondary pump. If no flow switch is installed, insert a jumper across X3.3/X3.4: See "Luster terminals" or "Cross connect PCB". The flow switch signal ….

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.