CA on a Viessmann Vitotronic 200: Protectn device primry: Compressor stops

Short answer

On a Viessmann heat pump, CA means: Protectn device primry: Compressor stops. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Protectn device primry: Compressor stops.

Part involved: Protectn device primry.

When it shows: Compressor stops.

Likely causes:

  • : Primary circuit pressure switch or frost stat has responded.
  • : Faulty power supply to fan.
  • : Fan blocked or faulty.
  • Contact humidistat has responded.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Check safety equipment at terminals X3.8 and X3.9: See "Cross connect PCB"/"Luster terminals". In systems without safety equipment or if the 24 V contact humidistat ….
  • If the following contact humidistats are used for cooling, check jumper at plug F11:.
  • Contact humidistat 230 V~, connection to X3.8/X3.9 – 24 V contact humidistat, connection to NC-Box.
  • : Check primary circuit. Check primary pump and/or well pump. Replace the pump if required.
  • : Check electrical connections at the fan. Carry out mechanical check of fan. The switching signal can be tested at terminal 215.3: See "Main PCB". ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026