BB on a Viessmann Vitotronic 200: Fault, PWM signal from secondary pump (actual speed)

Short answer

On a Viessmann heat pump, BB means: Fault, PWM signal from secondary pump (actual speed). The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Fault, PWM signal from secondary pump (actual speed).
  • KM BUS mixer cooling: No cooling mode.

Part involved: Fault, PWM signal from secondary pump (actual speed); KM BUS mixer cooling.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor remains in operation. Secondary pump continues to run at previously set speed, without monitoring. No cooling mode.

Likely causes:

  • Fault, PWM signal from secondary pump (actual speed).
  • Communication fault KM BUS or internal fault in extension kit, NC-Box for cooling circuit. (cont.).

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the room thermostat/remote control and time-program settings are as expected.

What the engineer will check

  • Check PWM signal at secondary pump. Check signal at connection J26 on the EEV PCB: See "EEV PCB [4-6] / [4-7] ". Replace the secondary ….
  • Check connections and parameter settings.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.