BA on a Viessmann Vitotronic 200: Secondary pump electrical fault

Short answer

On a Viessmann heat pump, BA means: Secondary pump electrical fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Secondary pump electrical fault.
  • KM BUS mixer HC: Mixer is closed.; Heating circuit pump is started (frost protection).

Part involved: Secondary pump electrical fault; KM BUS mixer HC.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Mixer is closed.; Heating circuit pump is started (frost protection).

Likely causes:

  • Secondary pump electrical fault.
  • Communication fault KM BUS or internal fault in extension kit, mixer M2/M3.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Carry out electrical check of secondary pump. Vitocal 200-G/222-G: Check voltage at connections J5.
  • and J17 on the EEV PCB. Vitocal 300-G/333-G: Check voltage at connection J20 on.
  • the EEV PCB. See "EEV PCB [4-6] / [4-7] ". Replace the secondary pump if required.
  • Check extension kit connections and code.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).