B0 on a Viessmann Vitotronic 200: Fan communication fault

Short answer

On a Viessmann heat pump, B0 means: Fan communication fault. The heat pump keeps running. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Fan communication fault.
  • Device recognition: Heat pumps with refrigerant circuit controller [7-1] : Heat pump starts. Refrigerant circuit runs with reduced efficiency.; Other heat pumps: The heat pump does not start.

Part involved: Fan communication fault; Device recognition.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Fan off, compressor remains in operation. Heat pumps with refrigerant circuit controller [7-1] : Heat pump starts. Refrigerant circuit runs with reduced efficiency.; Other heat pumps: The heat pump does not start.

Likely causes:

  • Fan communication fault.
  • Parameter "5030 Output compressor stage" is set incorrectly.
  • Error in recognising appliance version, incorrect coding card or PCBs faulty Vitocal 300-A, type AWO-AC 301.B:.
  • Cable harness for pressure sensor and fill level sensor in refrigerant collector faulty.
  • Charge level sensor of refrigerant collector faulty.

Is it safe?

Does the heat pump stop?No
Engineer needed?Yes

The heat pump keeps running.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check plug at connection J19: See.
  • "EEV PCB [4] ". Check luster terminals in the heat.
  • pump terminal area if necessary.
  • Correct setting for "5030 Output compressor stage".
  • Check the coding card: See "Controller and sensor PCB". Replace the coding card if necessary.
  • Check PCBs. Replace PCBs if required.
  • Vitocal 100-S/111-S: Check the ID of the jumper (blue) on the main PCB of the outdoor unit: See chapter "Main PCB [7] / [7-1] ".
  • Vitocal 200-A/200-S/222-A/222-S: Check the DIP switch on the EEV PCB of the outdoor unit: See chapter "EEV PCB [4-3] / [4-4] ".
  • Vitocal 200-G/222-G/300-G/333-G: Check the DIP switch on the EEV PCB: See chapter "EEV PCB [4-6] / [4-7] ".
  • Vitocal 300-A, type AWO-AC 301.B: Check cable harness and/or fill level sensor for refrigerant collector: See chapter "EEV PCB [4] ". Note After removing the ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026