ADViessmann · Vitotronic 200

AD on a Viessmann Vitotronic 200: Current of power factor correction filter too high (detected via software)

Short answer

On a Viessmann heat pump, AD means: Current of power factor correction filter too high (detected via software). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Current of power factor correction filter too high (detected via software).
  • Vitocal 300-G/333-G: Current of power factor correction filter too high (detected via software).
  • Mixer heating/DHW: No changeover between heating mode and DHW heating.

Part involved: Current of power factor correction filter too high (detected via software); Vitocal 300-G/333-G: Current of power factor correction filter too high (detected via …; Mixer heating/DHW.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No changeover between heating mode and DHW heating.

Likely causes:

  • Current of power factor correction filter too high (detected via software).
  • Vitocal 300-G/333-G: Current of power factor correction filter too high (detected via software).
  • 3-way diverter valve "Heating/DHW heating" is faulty.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Replace inverter.
  • Check function of 3-way diverter valve (see "Function check") Check voltage at terminal 211.4 (see "main PCB"); replace 3-way diverter valve if necessary.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026