Heat pumps · Error codes · Viessmann
AAViessmann · Vitotronic 200

AA on a Viessmann Vitotronic 200: Current phase L2 of compressor too high

Short answer

On a Viessmann heat pump, AA means: Current phase L2 of compressor too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Current phase L2 of compressor too high.
  • Vitocal 300-G/333-G: Current phase L2 of compressor too high.
  • Cancel defrost: : Compressor remains off until the flow temperature in the secondary circuit has reached 15 °C. Booster heaters are started if required (instantaneous heating water heater or external ….

Part involved: Current phase L2 of compressor too high; Vitocal 300-G/333-G: Current phase L2 of compressor too high; Cancel defrost.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF : Compressor remains off until the flow temperature in the secondary circuit has reached 15 °C. Booster heaters are started if required (instantaneous heating water heater or external heat generator). : Switch to central heating/DHW heating.

Likely causes:

  • Current phase L2 of compressor too high.
  • Vitocal 300-G/333-G: Current phase L2 of compressor too high.
  • Flow or return temperature in the secondary circuit too low during defrosting.
  • The pipework flow rate may be too low.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Test coil resistance at compressor. Resistance on all windings must be similar (±10 %). For mΩ use a suitable measuring device.
  • Replace compressor and/or inverter if required.
  • Replace compressor and/or inverter if necessary.
  • Provide additional heating water buffer cylinder in the secondary circuit return. ! Please note If the temperature in the secondary circuit is too low, the ….

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026