Heat pumps · Error codes · Viessmann
A9Viessmann · Vitotronic 200

A9 on a Viessmann Vitotronic 200: Current phase L1 of compressor too high

Short answer

On a Viessmann heat pump, A9 means: Current phase L1 of compressor too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Current phase L1 of compressor too high.
  • Vitocal 300-G/333-G: Current phase L1 of compressor too high.
  • Heat pump: Compressor is switched off.; Central heating and DHW heating occurs with other heat sources enabled for this purpose, e.g. an external heat generator or instantaneous heating water heater. ….

Part involved: Current phase L1 of compressor too high; Vitocal 300-G/333-G: Current phase L1 of compressor too high; Heat pump.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Compressor is switched off.; Central heating and DHW heating occurs with other heat sources enabled for this purpose, e.g. an external heat generator or instantaneous heating water heater.; The operation with booster heaters depends on the setting "Operating status after ….

Likely causes:

  • Current phase L1 of compressor too high.
  • Vitocal 300-G/333-G: Current phase L1 of compressor too high.
  • Heat pump faulty.
  • Safety high pressure switch has responded: See "C9 Refrigerant circ (SHD)".
  • One of the following events has occurred:.
  • High pressure limit was exceeded 3 times within 60 min (Vitocal 100-S/111-S only).
  • Low pressure limit was undershot twice within 40 min (Vitocal 100-S/111-S only).
  • Flow switch has responded 9 times.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
  • Check the outdoor unit (air source models) is not blocked by leaves, debris or snow.

What the engineer will check

  • Test coil resistance at compressor. Resistance on all windings must be similar (±10 %). For mΩ use a suitable measuring device.
  • Replace compressor and/or inverter if required.
  • Replace compressor and/or inverter if necessary.
  • Calling up further heat pump messages: "Message history".
  • Observe messages from the refrigerant circuit controller: "Diagnosis" "Refrigerant circuit" "Message history".
  • Check flow rates.
  • Check safety high pressure switch.
  • Check flow and return temperature sensors in the primary/secondary circuit. Note After removing the fault, switch the appliance first off and then on again.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026