SolarpunkHomes
Sign inCall us · +44 7510 081687
Heat pumps
Heat pumps · Error codes · Viessmann
A8Viessmann · Vitotronic 200

A8 on a Viessmann Vitotronic 200: Compressor drive overheated

Short answer

On a Viessmann heat pump, A8 means: Compressor drive overheated. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Compressor drive overheated.
  • Vitocal 300-G/333-G: Compressor drive overheated.
  • Heating circ. pump HC1: Temperature increase in heating circuit without mixer A1/HC1.

Part involved: Compressor drive overheated; Vitocal 300-G/333-G: Compressor drive overheated; Heating circ. pump HC1.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Temperature increase in heating circuit without mixer A1/HC1.

Likely causes:

  • Compressor drive overheated.
  • Vitocal 300-G/333-G: Compressor drive overheated.
  • No flow (circulation pump shut down).

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Test coil resistance at compressor. Resistance on all windings must be similar (±10 %). For mΩ use a suitable measuring device.
  • Replace compressor and/or inverter if required.
  • Replace compressor and/or inverter if necessary.
  • Measure voltage at terminal 212.2 (see "main PCB") and check pump mechanically; replace if necessary.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026