A6 on a Viessmann Vitotronic 200: Secondary pump: No flow rate in the secondary circuit: Secondary pump is not running.; The change in the secondary circuit flow temperature for central heating/cooling is insufficient

Short answer

On a Viessmann heat pump, A6 means: Secondary pump: No flow rate in the secondary circuit: Secondary pump is not running.; The change in the secondary circuit flow temperature for central heating/cooling is insufficient. The manual does not say whether the heat pump stops. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manual says: Secondary pump: No flow rate in the secondary circuit: Secondary pump is not running.; The change in the secondary circuit flow temperature for central heating/cooling is insufficient.

Part involved: Secondary pump.

When it shows: No flow rate in the secondary circuit: Secondary pump is not running.; The change in the secondary circuit flow temperature for central heating/cooling is insufficient.

Likely causes:

  • Secondary pump mechanical fault.
  • Secondary pump electrical fault.
  • Secondary pump run dry.

Is it safe?

Does the heat pump stop?Not stated
Engineer needed?Yes

The manual does not say whether the heat pump stops.

Resetting itself: Not stated per code; Vitotronic messages remain until the cause is removed and are acknowledged with OK (6150133 p.82). Unremedied acknowledged faults are redisplayed the following day.

Manual reset: Acknowledge with OK on the programming unit (user level permitted per 5817913 p.56-57) after the cause is remedied.

What you can check

  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Carry out mechanical check of secondary pump. Measure the voltage at the following connections:.
  • Vitocal 200-G/222-G: Connections J5 and J17 on the EEV PCB: See "EEV PCB [4-6] / [4-7] ".
  • Vitocal 300-G/333-G: Connections J5 and J20 on the EEV PCB: See "EEV PCB [4-6] / [4-7] ".
  • Other heat pumps: Connection 211.2: See "Main PCB". Replace the secondary pump if required.

Who to ask for: Viessmann-trained heat pump installer/service engineer.

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.