9E on a Viessmann Vitotronic 200: 1 phase of inverter supply voltage missing

Short answer

On a Viessmann heat pump, 9E means: 1 phase of inverter supply voltage missing. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • 1 phase of inverter supply voltage missing.
  • Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.
  • Voltage at inverter too low.
  • Delta T mon. solar: No solar DHW heating with solar control module, type SM1.

Part involved: 1 phase of inverter supply voltage missing.; Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.; Voltage at inverter too low; Delta T mon. solar.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No solar DHW heating with solar control module, type SM1.

Likely causes:

  • 1 phase of inverter supply voltage missing.
  • Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.
  • Voltage at inverter too low.
  • Insufficient or no flow rate in the solar circuit or.
  • Temperature limiter has responded.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check inverter power supply.
  • No action required; automatic reset of compressor.
  • Check solar circuit pump sF on solar control module, type SM1: See installation and service instructions for solar control module, type SM1.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026