9E on a Viessmann Vitotronic 200: 1 phase of inverter supply voltage missing
Short answer
On a Viessmann heat pump, 9E means: 1 phase of inverter supply voltage missing. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.
Reviewed 23 September 2026 · 1 source
What it means
The manuals for this range word it in different ways:
- 1 phase of inverter supply voltage missing.
- Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.
- Voltage at inverter too low.
- Delta T mon. solar: No solar DHW heating with solar control module, type SM1.
Part involved: 1 phase of inverter supply voltage missing.; Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.; Voltage at inverter too low; Delta T mon. solar.
When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No solar DHW heating with solar control module, type SM1.
Likely causes:
- 1 phase of inverter supply voltage missing.
- Vitocal 300-G/333-G: 1 phase of inverter supply voltage missing.
- Voltage at inverter too low.
- Insufficient or no flow rate in the solar circuit or.
- Temperature limiter has responded.
Is it safe?
| Does the heat pump stop? | Yes |
|---|---|
| Engineer needed? | Yes |
The heat pump stops until the fault clears or is reset.
Resetting itself: Not stated in 6150133.
Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.
What you can check
- This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
- Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
- You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
- Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.
What the engineer will check
- Check inverter power supply.
- No action required; automatic reset of compressor.
- Check solar circuit pump sF on solar control module, type SM1: See installation and service instructions for solar control module, type SM1.
Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.
Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).
What you might notice
Sources
- Service instructions Vitotronic 200 type WO1C heat pump control unit (air/water split & monobloc, brine/water) (6150133, 2023-07) ↗ · 6150133 VSA00004 · pages 171, 177, 185, 98 · Reviewed 23 September 2026
A code explains what the controller detected, not a confirmed root cause.
Reviewed: 23 September 2026