97Viessmann · Vitotronic 200

97 on a Viessmann Vitotronic 200: Voltage difference of individual phases too high (> 50 %)

Short answer

On a Viessmann heat pump, 97 means: Voltage difference of individual phases too high (> 50 %). The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 2 sources

What it means

The manuals for this range word it in different ways:

  • Voltage difference of individual phases too high (> 50 %).
  • Vitosolic error: No solar DHW heating with Vitosolic 200; No heating of the ice store.

Part involved: Voltage difference of individual phases too high (> 50 %); Vitosolic error.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No solar DHW heating with Vitosolic 200; No heating of the ice store.

Likely causes:

  • Voltage difference of individual phases too high (> 50 %).
  • Fault message from Vitosolic 200.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heat pump breaker/isolator in the consumer unit is ON (do not repeatedly reset a breaker or RCD that keeps tripping).

What the engineer will check

  • Replace inverter.
  • Check the compressor connecting.
  • cable. Replace the connecting cable if necessary. ! Please note 400 V appliances: An incorrect rotating field will irreparably damage the compressor. When replacing the ….
  • "Vitosolic 200" installation and service instructions.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.