Heat pumps · Error codes · Viessmann
94Viessmann · Vitotronic 200

94 on a Viessmann Vitotronic 200: Inverter communication fault

Short answer

On a Viessmann heat pump, 94 means: Inverter communication fault. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Inverter communication fault.
  • Cylinder sensor solar: No solar DHW heating with solar control module, type SM1.

Part involved: Inverter communication fault; Cylinder sensor solar.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No solar DHW heating with solar control module, type SM1.

Likely causes:

  • Inverter communication fault.
  • Short circuit, cylinder temperature sensor at solar control module, type SM1.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.

What the engineer will check

  • Isolate the inverter from the power.
  • supply. Then restore power supply. Replace inverter if the fault persists.
  • Check sensor % on solar control module, type SM1: See installation and service instructions for solar control module, type SM1.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026