Heat pumps · Error codes · Viessmann
91Viessmann · Vitotronic 200

91 on a Viessmann Vitotronic 200: Fan fault at inverter heat sink

Short answer

On a Viessmann heat pump, 91 means: Fan fault at inverter heat sink. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Fan fault at inverter heat sink.
  • Solar module sensor 10: No switching of the appliance connected at plug sS of the solar control module, type SM1 (circulation pump or 3-way diverter valve).

Part involved: Fan fault at inverter heat sink; Solar module sensor 10.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF No switching of the appliance connected at plug sS of the solar control module, type SM1 (circulation pump or 3-way diverter valve).

Likely causes:

  • Fan fault at inverter heat sink.
  • Short circuit, temperature sensor aÖ at solar control module, type SM1.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.
  • Note the 2-character message code and message text shown on the Vitotronic 200 display (press OK for details) and give them to your heating contractor (operating instructions 5817913 p.56).
  • You may acknowledge the message once with OK as described in the Vitotronic 200 operating instructions; if it reappears, do not keep acknowledging it - call your contractor.
  • Check the heating system pressure gauge reading and report a low reading to your contractor; make sure the filling loop is closed.

What the engineer will check

  • Check fan at inverter heat sink. Clean the fan if necessary: See "EEV PCB [2] ".
  • Check fan at inverter heat sink for leaks (see "Connection and wiring diagram"); clean if necessary.
  • Check sensor aÖ on solar control module, type SM1: See installation and service instructions for solar control module, type SM1.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification; Viessmann-trained heat pump installer/service engineer.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026