8F on a Viessmann Vitotronic 200: Compressor drive deactivated

Short answer

On a Viessmann heat pump, 8F means: Compressor drive deactivated. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Compressor drive deactivated.
  • Inverter blocked.
  • Vitocal 300-G/333-G: Inverter switched off.
  • Inverter switched off.

Part involved: Compressor drive deactivated; Inverter blocked; Vitocal 300-G/333-G: Inverter switched off; Inverter switched off.

When it shows: Type "Fault" (S) - triggers "05 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF.

Likely causes:

  • Compressor drive deactivated.
  • Inverter blocked.
  • Vitocal 300-G/333-G: Inverter switched off.
  • Inverter switched off.

Is it safe?

Does the heat pump stop?Yes
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • Check jumpers on inverter, terminals 4 to.
  • Observe the connection and wiring diagram for the heat pump: See "EEV PCB [2] ".
  • Replace inverter if necessary.
  • Switch OFF the power supply to the outdoor unit. Wait at least 2 min. Switch the power ON again. Replace inverter if the fault persists.
  • Check electrical connecting cable between inverter and compressor. Replace the connecting cable if necessary: See "Connection and wiring diagram".
  • Check Modbus connecting cable, inverter — EEV PCB.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026