86 on a Viessmann Vitotronic 200: Inverter power consumption too high

Short answer

On a Viessmann heat pump, 86 means: Inverter power consumption too high. The heat pump stops until the fault clears or is reset. An engineer is needed to fix the cause.

Reviewed 23 September 2026 · 1 source

What it means

The manuals for this range word it in different ways:

  • Inverter power consumption too high.
  • Inverter power consumption (IGBT module) permanently too high.
  • Vitocal 300-G/333-G: Inverter power consumption (IGBT module) permanently too high.
  • Inverter power consumption (IGBT) permanently too high.
  • Motor overload relay or safety equipment at the soft starter has responded.

Part involved: Inverter power consumption too high; Inverter power consumption (IGBT module) permanently too high; Vitocal 300-G/333-G: Inverter power consumption (IGBT module) permanently too high; Inverter power consumption (IGBT) permanently too high; Motor overload relay or safety equipment at the soft starter has responded.

When it shows: Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor OFF Type "Note" (H) - triggers "07 Refrigerant circuit" on the heat pump control unit. Heat pump characteristics: Compressor blocked for 4 min.

Likely causes:

  • Inverter power consumption too high.
  • Inverter power consumption (IGBT module) permanently too high.
  • Vitocal 300-G/333-G: Inverter power consumption (IGBT module) permanently too high.
  • Inverter power consumption (IGBT) permanently too high.
  • Motor overload relay or safety equipment at the soft starter has responded.

Is it safe?

Does the heat pump stop?Yes
SeverityWarning
Engineer needed?Yes

The heat pump stops until the fault clears or is reset.

Resetting itself: Not stated in 6150133.

Manual reset: Refrigerant circuit messages cannot be acknowledged in the message history (6150133 p.155); acknowledge the resulting 05/07/A9 message on the control unit.

What you can check

  • This code is only visible to engineers in the service menu (Diagnosis > Refrigerant circuit > Message history); homeowners see message 05, 07 or A9 - note that code and call your contractor.

What the engineer will check

  • Test coil resistance at compressor. Resistance on all windings must be similar (±10 %). For mΩ use a suitable measuring device.
  • No action required.
  • No action required: Compressor is automatically reset.

Who to ask for: Viessmann-trained heat pump engineer with F-gas refrigeration certification.

Certification: F-gas certificate (UK F-gas Regulations; Viessmann: refrigerant work by authorised refrigeration engineers only).

What you might notice

Sources

A code explains what the controller detected, not a confirmed root cause.

Reviewed: 23 September 2026